Skip to main content
Atmotube Technical Specifications

Detailed sensor specifications of the Atmotube PRO.

Updated over 2 months ago

TVOC sensor

Digital, auto calibration
Sampling rate: In app: 2 sec, CSV: 1 min

PM sensor

Sensirion SPS30
PM1, PM2.5, PM10

Sampling rate:

Always On (In app: 1 sec, CSV: 1 min), 5/10/15 min,

on demand

Temperature

Humidity

Pressure sensor

Sampling rate: In app: 1 sec, CSV: 1 min

Memory size

256 KB

History size

10 days

Bluetooth

5.0

Battery capacity

2000 mAh

Battery life

up to 10 days, depending on the measurement intervals

Weight

3.7 oz (104 g)

Size

Height x Width x Depth
3.4 x 2 x 0.9 in
86 x 50 x 22 mm

Measurement range and accuracy

TVOC output range

0 - 60 ppm

TVOC typical accuracy

15% of measured value

PM output range

1 - 1000 μg/m³

PM typical accuracy

PM1, PM2.5

0 to 100 μg/m³, [±5 μg/m³ + 5 % m.v.]
100 to 1000 μg/m³, ±10% m.v.

PM10

0 to 100 μg/m³, ±25 μg/m³

100 to 1000 μg/m³, ±25 % m.v.

Temperature*

±1°C (0-65°C)

Humidity

±3%RH

Pressure

±1 hPa

* Temperature value depends on the PCB temperature, sensor element self-heating and ambient temperature and is typically above ambient temperature.